The engineering principles and innovation that define precision electrical measurement. Every specification is backed by documented test data.
Our instruments are designed around a proprietary multi-stage analog-digital signal conditioning chain that delivers laboratory accuracy in field conditions.
Our 24-bit sigma-delta analog-to-digital converters provide 60,000-count resolution with true-RMS measurement bandwidth from DC to 100kHz. The oversampling architecture inherently rejects 50/60Hz power line noise without compromising measurement speed.
A multi-stage protection circuit incorporating MOVs, spark gaps, PTC fuses, and high-energy resistors provides measured immunity to voltage transients up to 8kV, 100kA — exceeding IEC 61010-1 requirements for CAT IV 600V installations.
Measurement safety is an engineering discipline, not a label. Every safety rating is independently verified through destructive and non-destructive testing.
All instruments are designed, prototyped, and production-tested to the full requirements of IEC 61010-1 and IEC 61010-2-033. Third-party type testing is performed by NRTL-accredited laboratories including UL, CSA, and TUV.
Our flagship multimeters and insulation testers carry a genuine CAT IV 600V / CAT III 1000V rating — the highest measurement category defined by IEC 61010. This enables safe use at the service entrance and primary supply level.
Beyond standard impulse testing, our instruments undergo arc blast exposure testing simulating worst-case fault conditions. Enclosures, test leads, and probe tips are evaluated for flame propagation and shrapnel containment.
Every instrument leaves our facility with a traceable calibration certificate. Our 12 calibration laboratories worldwide maintain accreditation to ISO/IEC 17025:2017 — the international standard for testing and calibration laboratory competence.
NIST (USA) / PTB (Germany) / NMI (Australia) traceable through unbroken chains of calibration with documented measurement uncertainties at every level.
Full GUM-compliant measurement uncertainty analysis provided with every calibration certificate, covering Type A and Type B uncertainty contributions.
Calibration performed in temperature-controlled environments (23C ± 1C, 45% ± 10% RH) with continuous monitoring and recording of ambient conditions.
Transform standalone instruments into an enterprise measurement network with wireless connectivity, cloud analytics, and SCADA integration.
Low-energy wireless data transfer from instrument to mobile device or gateway with 30-meter range and AES-128 encryption.
Trend analysis, threshold alerts, and automated reporting through our secure cloud platform with API access for ERP integration.
Modbus TCP and BACnet protocol support for direct integration with building management and industrial control systems.
On-board data recording at up to 1-second intervals with 10,000+ reading capacity and timestamped CSV export.
Download datasheets, application notes, and white papers for any instrument in our range.